120W LED Linear Explosion Proof Light for Class I, Division 2 Hazardous Locations - 16800 lumens - 400 MH Equivalent - 4000K/5000K
Features
- Certified by UL for use in hazardous locations: Class I, Division 2, Groups A, B, C, & D
- Sealed explosion-proof construction, impact and shock resistant
- High efficacy of 140 lm/W
- UL 844, 5 year warranty
- Surface, conduit, and hanging mount options available (sold separately)
Try asking:
Loading recommendations...
Overview
Product Details:
- Certified by UL - UL 1598 and UL 844
- T-Class Rating - T5
- 120-277 VAC input voltage
- Includes powder coated yoke mount
- Gray powder-coated housing has IK10 impact resistance rating
- Clear glass lens is rated to IK08
- 50000 hour LED lifetime
- Surge Protection 10 kV L/N-PE 6 kV L-N
- Wide 110° beam angle
- 70+ CRI
- Instant-on light with no delay, flicker, or buzzing
- Improved color rendering compared to HPS, LPS, MV
- Consistent color maintenance over time
- Dimmable: 3-in-1 (0-10V / PWM / Resistor Dimming)
- Operating temperature of -40°-122° F (-40°-50°C)
Ask About This Product
Get instant AI-powered answers
Try asking:
Products Mentioned
Press Enter to send, Shift+Enter for new line
Responses are AI-generated from product documentation. For confirmation or more information, contact Super Bright LEDs customer service.
Conversations are recorded for quality assurance. More information
Ask About This Product
Get instant AI-powered answers
Try asking:
Products Mentioned
Press Enter to send, Shift+Enter for new line
Responses are AI-generated from product documentation. For confirmation or more information, contact Super Bright LEDs customer service.
Conversations are recorded for quality assurance. More information
Try asking:
Specifications
| Ambient Operating Temperature | -40 to 50 °C (-40 to 122 °F) |
|---|---|
| Beam Angle | 110° |
| Brand | Super Bright LEDs |
|
Certifications/Compliance
Certifications/Compliance
Standards and certifications comprise a vast number of companies and compliances that serve specific purposes—primarily addressing safety, environmental impact and energy efficiency, and sanitation. They are divided into categories for each product type and certification type to allow for very specific qualifications related to each product. When this system is being used as intended, it gives consumers, installers, suppliers, and anyone else that may be involved confidence that the product is safe and will work well in their application. The most common UL and ETL certifications relate to safety and installation, although they do also provide some sanitation-related certifications (using NSF standards). Another common certification body is the DLC, which specializes in certifying the performance of a light—mainly related to environmental impact and electrical efficiency. Learn more about different certification types here . |
Certified by UL |
|
CRI
CRI
![]() |
70+ |
|
Current Draw
Current Draw
Current draw is calculated using the following formula: W/V = A, where W = the amount of power your light needs (wattage), V is the electrical system voltage (e.g., 120V AC), and A = amps. An ampere or amp (A) is the standard unit for electrical current. A milliamp (mA) equals one-thousandth of an amp, or 1000 mA is equivalent to 1 A.
Choosing LED fixtures with the correct amperage ensures safe and proper operation, preventing damage or injury. We recommend having all electrical components and fixtures installed by a certified professional electrician or lighting technician in compliance with all relevant standards and regulations. |
1 A @ 120 VAC, 430 mA @ 277 VAC |
| Dimmable | Yes |
|
Dimming Type
Dimming Type
0-10V Dimming: This type of dimming control is the most popular and newest style for compatible dimmable power supplies. It works by varying the voltage from 0 to 10 VDC. A 10-volt signal on the dimming wire will allow maximum current flow to the LEDs for maximum intensity. A 0.6-volt signal on the dimming wires allows 6% of the current to flow from the power supply, dimming the LEDs to approximately 6% of full intensity. 1-10V Dimming: This type of dimming control is an older style that is being replaced with 0-10V dimming control. It works by varying the voltage from 1-10 VDC. A 10-volt signal on the dimming wire will allow maximum current flow to the LEDs for maximum intensity. A 1-volt signal on the dimming wire allows 10% of the current to flow from the power supply, which generates approximately 10% of the maximum intensity for the LEDs. TRIAC Dimming: TRIAC dimmers are typical household dimmers sold in hardware stores by brands like Lutron and Leviton. They rely on a semiconductor device called a TRIAC (Triode for Alternating Current). Adjusting the dimmer switch alters the timing at which the TRIAC conducts electricity in each AC cycle, modulating the energy delivered to the light bulb and resulting in adjustable brightness levels. Pulse-Width Modulation Dimming: This type of dimming control adjusts the output current based on the duty cycle. As the duty cycle increases, the current will increase, and the LEDs will be brighter. Conversely, if the duty cycle decreases, the current will decrease, and the LEDs will be dimmer. Resistive Dimming: Resistive dimming can be fixed or variable. If a fixed dimming level is required, a simple resistor is needed to dim the LEDs to a particular level. A potentiometer can serve this purpose if a varying dimmable level is desired. By changing the resistance value of the potentiometer, the output current of the power supply changes, and the LED intensity changes. Controlling a single power supply will require a 100K ohm potentiometer for 100% intensity (100K ohm) to approximately 10% intensity (10K ohm) based on the wiper position. |
3-in-1 (0-10V / PWM / Resistor Dimming) |
| Efficacy | 140 lm/W |
|
Environmental Rating
Environmental Rating
![]() |
Suitable for Wet Locations, Waterproof |
| Equivalency | 400 Watt Metal-Halide |
| Finish | Gray |
|
Hazardous Location Rating
Hazardous Location Rating
![]() |
Class I, Division 2, Groups A, B, C, D |
| Input Connection Type | Terminal Block |
| Integrated Surge Protection | 10 kV (L/N-PE), 6 kV (L-N) |
|
IP Rating
IP Rating
![]() |
IP66 |
| Rated Life (L70) | 50000 Hours |
| Lens Color | Clear |
| Lens Type | Glass |
| Lumens | 16800 Lumens |
| Mount Type | Yoke Bracket |
| Operating Voltage | 120-277 VAC |
| Wattage | 120 Watts |
| Power Factor | ≥0.9 |
| Product Materials | Aluminum Housing, Glass Lens |
| Product Weight | 35.3 lb (16.0 kg) |
|
T-Class Rating
T-Class Rating
![]() |
T5 |
| UL File Number | E366643, E483625 |
| Warranty | 5 Year |
| Part NO |
CCT
CCT
![]() |
LED Color |
|---|---|---|
| EPLL-40K120-UGN-110 | 4000K | Natural White |
| EPLL-50K120-UGN-110 | 5000K | Cool White |
Accessories & Power Supplies
Reviews
Review Guidelines
Super Bright LEDs reads and approves all reviews before listing them on the website. Below you will find a list of reasons that can result in your review being rejected.
- Review text does not pertain to the product
- Abusive and offensive language
- Photos are not related to the reviewed product
- Any violation of laws and/or copyrighted material
- Unrelated hyperlinks/URLs